diff --git a/generated/recommonamplifierparameters.go b/generated/recommonamplifierparameters.go
new file mode 100644
index 0000000..7cd00cf
--- /dev/null
+++ b/generated/recommonamplifierparameters.go
@@ -0,0 +1,140 @@
+/*
+ * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
+ *
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+ * http://www.apache.org/licenses/LICENSE-2.0
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ * https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// ReCommonAmplifierParametersClassID is the 16-bit ID for the OMCI
+// Managed entity RE common amplifier parameters
+const ReCommonAmplifierParametersClassID ClassID = ClassID(328)
+
+var recommonamplifierparametersBME *ManagedEntityDefinition
+
+// ReCommonAmplifierParameters (class ID #328)
+// This ME organizes data associated with each OA supported by the RE. The management ONU
+// automatically creates one instance of this ME for each upstream or downstream OA.
+//
+// Relationships
+// An instance of this ME is associated with an instance of the RE downstream amplifier or RE
+// upstream amplifier ME.
+//
+// Attributes
+// Managed Entity Id
+// NOTE - The type of the linked ME can be determined by uniqueness of slot and port.
+//
+// Gain
+// Gain: This attribute reports the current measurement of the OA's gain, in decibels. Its value is
+// a 2s complement integer with 0.25-dB granularity, and with a range from -32-dB to 31.5-dB. The
+// value 0x7F indicates that the current measured gain is 0, i.e., negative infinity in decibels
+// terms. (R) (optional) (1-byte)
+//
+// Lower Gain Threshold
+// Lower gain threshold: This attribute specifies the gain the RE uses to declare the low gain
+// alarm. Valid values are 0-dB (coded as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF
+// selects the RE's internal policy. (R,-W) (optional) (1-byte)
+//
+// Upper Gain Threshold
+// Upper gain threshold: This attribute specifies the gain the RE uses to declare the high gain
+// alarm. Valid values are 0-dB (coded as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF
+// selects the RE's internal policy. (R,-W) (optional) (1-byte)
+//
+// Target Gain
+// Target gain: This attribute specifies the target gain, when the operational mode of the parent
+// RE downstream or upstream amplifier is set to constant gain mode. Valid values are 0-dB (coded
+// as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF selects the RE's internal policy.
+// (R,-W) (optional) (1-byte)
+//
+// Device Temperature
+// Device temperature: This attribute reports the temperature in degrees Celcius of the active
+// device (SOA or pump) in the OA. Its value is a 2s complement integer with granularity
+// 1/256-degree-C. (R) (optional) (2-bytes)
+//
+// Lower Device Temperature Threshold
+// Lower device temperature threshold: This attribute is a 2s complement integer that specifies the
+// temperature the RE uses to declare the low temperature alarm. Valid values are -64 to
+// +63-degree-C in 0.5-degree-C increments. The default value 0x7F selects the RE's internal
+// policy. (R,-W) (optional) (1-byte)
+//
+// Upper Device Temperature Threshold
+// Upper device temperature threshold: This attribute is a 2s complement integer that specifies the
+// temperature the RE uses to declare the high temperature alarm. Valid values are -64 to
+// +63-degree-C in 0.5-degree-C increments. The default value 0x7F selects the RE's internal
+// policy. (R,-W) (optional) (1-byte)
+//
+// Device Bias Current
+// Device bias current: This attribute contains the measured bias current applied to the SOA or
+// pump laser. Its value is an unsigned integer with granularity 2-mA. Valid values are 0 to
+// 512-mA. (R) (optional) (1-byte)
+//
+// Amplifier Saturation Output Power
+// Amplifier saturation output power: This attribute reports the saturation output power of the
+// amplifier as specified by the manufacturer. Its value is an unsigned integer referred to 1-mW
+// (i.e., dBm), with 0.1-dB granularity. (R) (optional) (2-bytes)
+//
+// Amplifier Noise Figure
+// Amplifier noise figure: This attribute reports the intrinsic noise figure of the amplifier, as
+// specified by the manufacturer. Its value is an unsigned integer with 0.1-dB granularity (R)
+// (optional) (1-byte)
+//
+// Amplifier Saturation Gain
+// Amplifier saturation gain: This attribute reports the gain of the amplifier at saturation, as
+// specified by the manufacturer. Its value is an unsigned integer with 0.25-dB granularity, and
+// with a range from 0 to 63.75-dB. (R) (optional) (1-byte)
+//
+type ReCommonAmplifierParameters struct {
+ ManagedEntityDefinition
+ Attributes AttributeValueMap
+}
+
+func init() {
+ recommonamplifierparametersBME = &ManagedEntityDefinition{
+ Name: "ReCommonAmplifierParameters",
+ ClassID: 328,
+ MessageTypes: mapset.NewSetWith(
+ Get,
+ Set,
+ ),
+ AllowedAttributeMask: 0xffe0,
+ AttributeDefinitions: AttributeDefinitionMap{
+ 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
+ 1: ByteField("Gain", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, true, false, 1),
+ 2: ByteField("LowerGainThreshold", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, false, 2),
+ 3: ByteField("UpperGainThreshold", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, true, false, 3),
+ 4: ByteField("TargetGain", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
+ 5: Uint16Field("DeviceTemperature", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5),
+ 6: ByteField("LowerDeviceTemperatureThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6),
+ 7: ByteField("UpperDeviceTemperatureThreshold", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7),
+ 8: ByteField("DeviceBiasCurrent", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8),
+ 9: Uint16Field("AmplifierSaturationOutputPower", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9),
+ 10: ByteField("AmplifierNoiseFigure", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10),
+ 11: ByteField("AmplifierSaturationGain", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11),
+ },
+ Access: CreatedByOnu,
+ Support: UnknownSupport,
+ }
+}
+
+// NewReCommonAmplifierParameters (class ID 328) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewReCommonAmplifierParameters(params ...ParamData) (*ManagedEntity, OmciErrors) {
+ return NewManagedEntity(*recommonamplifierparametersBME, params...)
+}