)]}'
{
  "log": [
    {
      "commit": "66aa41d5b0c8a13ea60634a04db89768b9114e28",
      "tree": "03f7d6fa9ea6b8583c8c915713bd791453d26081",
      "parents": [
        "4f42f637e6947f3421ea4b240e97e3c458c0c6f8"
      ],
      "author": {
        "name": "Rouzbahan Rashidi-Tabrizi",
        "email": "rrashidi@ciena.com",
        "time": "Fri Feb 24 09:30:30 2017 -0500"
      },
      "committer": {
        "name": "khenaidoo Nursimulu",
        "email": "knursimu@ciena.com",
        "time": "Sat Feb 25 07:07:00 2017 -0800"
      },
      "message": "Continue II: Fix for PONSIM exit issue with execption\n\nChange-Id: Ib0544a559f60b5b03c767926c9c7c69016faeb7c\n"
    },
    {
      "commit": "4f42f637e6947f3421ea4b240e97e3c458c0c6f8",
      "tree": "1b38270e5f13e376783bbcfbe611cc480bd447d4",
      "parents": [
        "c35866bfa4779fbfc4a9e69acda3ec0340f808fe"
      ],
      "author": {
        "name": "Rouzbahan Rashidi-Tabrizi",
        "email": "rrashidi@ciena.com",
        "time": "Thu Feb 23 17:13:31 2017 -0500"
      },
      "committer": {
        "name": "khenaidoo Nursimulu",
        "email": "knursimu@ciena.com",
        "time": "Sat Feb 25 07:07:00 2017 -0800"
      },
      "message": "Continue: Fix for PONSIM exit issue with execption\n\nChange-Id: I28a4de3085b50b28773d01057bddb98ba696e237\n"
    },
    {
      "commit": "c35866bfa4779fbfc4a9e69acda3ec0340f808fe",
      "tree": "3ae97cf06ae40e4ccc49244bfa833f39fd42df11",
      "parents": [
        "bf974d075d763651a0a28c6cdd2d8b1365be6dd7"
      ],
      "author": {
        "name": "Rouzbahan Rashidi-Tabrizi",
        "email": "rrashidi@ciena.com",
        "time": "Thu Feb 23 14:57:58 2017 -0500"
      },
      "committer": {
        "name": "khenaidoo Nursimulu",
        "email": "knursimu@ciena.com",
        "time": "Sat Feb 25 07:07:00 2017 -0800"
      },
      "message": "Fix for PONSIM exit issue with execption\n\nChange-Id: Id249cb67760c8aa5708dccca63b60f06608d4900\n"
    },
    {
      "commit": "3e6f0898bbeba59a02fdb99911a7b80989ff8bde",
      "tree": "0f594768c537cb7baef3d8ab6c7633cce7599f7e",
      "parents": [
        "c99552dd22611a1ba510d60fb8b58dd91c6109ea"
      ],
      "author": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Thu Jan 19 11:51:40 2017 -0800"
      },
      "committer": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Thu Jan 19 11:51:53 2017 -0800"
      },
      "message": "FrameIO to allow sharing same Linux interface\n\nChange-Id: I30a8dd660477980069801952861d38e0dbe09739\n"
    },
    {
      "commit": "3578a1c3ac3c9898acff32b1e8b940ef18ceac1e",
      "tree": "428c3eb476abaac4ca390972e0990340c3836d78",
      "parents": [
        "6a5107c865a46df9a6c778d8d34e300621232264"
      ],
      "author": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Tue Jan 10 15:29:02 2017 -0800"
      },
      "committer": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Tue Jan 10 20:20:30 2017 -0800"
      },
      "message": "Expand field/action conversion scope of ofagent\n\nOfagent did not parse all fields back from protobuf to lexi,\nhence ONOS was not able to confirm downloaded flows. This\nmade her unhappy.\n\nAlso, DHCP config info is added to ONOS netcfg.json.\n\nChange-Id: I57ac5d3b4d14c8c52feb52e08bb420c15809238e\n"
    },
    {
      "commit": "6a5107c865a46df9a6c778d8d34e300621232264",
      "tree": "02db17e968a9c323942b6741d70ce6b7a6fa187c",
      "parents": [
        "6f746645ac6fa03c2c7c37c3ebbb33a2830f5d3f"
      ],
      "author": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Mon Jan 09 23:42:41 2017 -0800"
      },
      "committer": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Tue Jan 10 00:54:50 2017 -0800"
      },
      "message": "Adding support for OLT side metadata field\n\nDue to historic reasons, ONOS injects a metadata match field into one\nof the downstream unicats flow rules, which was not yet handled by voltha.\nThat is fixed and tested now.\n\nChange-Id: Ic8a47de515fa5837a70941be22da9e2d6539f614\n"
    },
    {
      "commit": "656ecc6676367d7483667550fa91046d7a8c0719",
      "tree": "4f934b1feda7c7032da3a62d09f4e101929ff5fa",
      "parents": [
        "313c4be4cfc0b0e1bb2551efed6489333b195bfb"
      ],
      "author": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Wed Dec 28 15:08:23 2016 -0800"
      },
      "committer": {
        "name": "Zsolt Haraszti",
        "email": "zharaszt@ciena.com",
        "time": "Thu Dec 29 00:15:43 2016 -0800"
      },
      "message": "PONSIM: PON simulator with real dataplane handling\n\nThis was needed because neither CPQD nor OVS can handle\nboth zero-tagged packets and 802.1ad (QinQ).\n\n- extensive unittest proves ponsim functional correctness\n  (for the common use-cases needed in the PON scenario)\n- integrated with frameio and coupled with a rather\n  simple gRPC NBI, ponsim can be operated from Voltha\n  just like a real PON system\n- posim_olt/_onu adapters added to Voltha to work on\n  ponsim\n- CLI can be used to preprovision and activate a PONSIM\n  instance (e.g., preprovision_olt -t ponsim_olt -H localhost:50060)\n- Some of olt-oftest:olt-complex testcases can be run on\n  the ponsim device (in vagrant/Ubuntu environment),\n  but there are some remaining issues to work out:\n  - barrier calls in OF do not guaranty that the flow\n    is already installed on the device. This is a generic\n    issue, not just for ponsim.\n  - the whole test framework is inconsistent about zero-\n    tagged vs. untagged frames at the ONUs, while ponsim\n    is rather pedantica and does exactly what was defined\n    in the flows.\n\nChange-Id: I0dd564c932416ae1566935492134cb5b08113bdc\n"
    }
  ]
}
