  "commit": "85855e8445109a2f56014223cb7e6cb814cd4288",
  "tree": "721e3384a00dfc8611af22b032811c7164310bbc",
  "parents": [
    "9be9fd476427d60d325899cbab7c09c1eeba9b92"
  ],
  "author": {
    "name": "Matt Jeanneret",
    "email": "mj3580@att.com",
    "time": "Tue Jan 29 16:01:36 2019 -0500"
  },
  "committer": {
    "name": "Matt Jeanneret",
    "email": "mj3580@att.com",
    "time": "Tue Jan 29 22:20:31 2019 +0000"
  },
  "message": "BUGFIX: Disable mib resync and mds check allowing onu disable/enable to work\n\nFor certain onu there is always a mib mismatch (MDS value) between whats stored\nin the mib db and whats configured on the onu.  This results in numerous\nreattempts at resyncing the mib.  In cases were Volatile mib storage is\nused this also prevent an onu from being re-enabled.\n\nLong term need to discover why certain onu me, namely vlan_tagging_operation_table\ncannot be synced properly.\n\nChange-Id: I8e324cec7540a9a4e12b0cb18b28f93e317f8d65\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "6791ce48ac98c7af07e4ad91228d8f1077f06b4b",
      "old_mode": 33188,
      "old_path": "voltha/adapters/brcm_openomci_onu/brcm_openomci_onu.py",
      "new_id": "ad89dc89a503c9510eee9f47fb0bfc8109eb11e2",
      "new_mode": 33188,
      "new_path": "voltha/adapters/brcm_openomci_onu/brcm_openomci_onu.py"
    },
    {
      "type": "modify",
      "old_id": "f63c6a4cb0fb97a25b623fa2003be5128bda625b",
      "old_mode": 33188,
      "old_path": "voltha/adapters/brcm_openomci_onu/omci/brcm_mib_sync.py",
      "new_id": "53ca22dafc89e056d528402be70003c241cc944e",
      "new_mode": 33188,
      "new_path": "voltha/adapters/brcm_openomci_onu/omci/brcm_mib_sync.py"
    }
  ]
}