  "commit": "d52d6a67cd2ed3042175836cd7a8a29012652a4d",
  "tree": "54262215da6d2a316dc9e54eb29ba6f64adb466d",
  "parents": [
    "2bcbab04574ad8eb61b47f91b2c5369225c8b515"
  ],
  "author": {
    "name": "Matt Jeanneret",
    "email": "mj3580@att.com",
    "time": "Fri Oct 04 11:51:42 2019 -0400"
  },
  "committer": {
    "name": "David Bainbridge",
    "email": "dbainbri@ciena.com",
    "time": "Wed Oct 09 21:16:36 2019 +0000"
  },
  "message": "VOL-1330:  Limit the number of failed resync attempts.\n\nRather than trying to resync forever and leaving the onu\nunusable, limit the tries to a configurable amount.  Some onu\nrefuse to mib upload after being provisioned, and this prevents\nan in-sync/restore in service if the olt or voltha is restarted\nand the onu is not.\n\nIf the limit is hit force reset the onu and re-upload the\nmib.  A reset onu always allows mib upload.\n\nThis deals with onu that refuse to upload their mib after being\nconfigured, and becoming disconnected/reconnected from the pon.\ni.e fiber pull or olt restart and the onu did *not* restart.\n\nChange-Id: I0451b9954980f36efd035fbfc381bdc328aa8571\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "8d8d54c359614f5083197090f0407696f3af33aa",
      "old_mode": 33188,
      "old_path": "pyvoltha/adapters/extensions/omci/state_machines/mib_sync.py",
      "new_id": "d38cbafbde0bd2ebb716e9f6c83ea9aa8b9f114f",
      "new_mode": 33188,
      "new_path": "pyvoltha/adapters/extensions/omci/state_machines/mib_sync.py"
    }
  ]
}