)]}'
{
  "log": [
    {
      "commit": "834c28fc24acb1c26efcf824c52484c3c6f4d74f",
      "tree": "3a2e27ee2ce90d635442c9bcef75a6c49f5f1483",
      "parents": [
        "cd58a7ba050a738f22b52a37926db1dcbc914636"
      ],
      "author": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Thu Dec 05 18:26:22 2019 -0800"
      },
      "committer": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Mon Dec 09 22:10:28 2019 +0000"
      },
      "message": "EDGEPOD-60 Add support of multiple UPFs\n\n- Enable configuring multiple UPF mode\n- Add support of ZMQ mode when multple UPF enabled\n- Change to create three types of services for each application,\n  cluster IP, headless, and external\n\nChange-Id: Ic004a4ff7cdc5708d28ce2717677041f71b4d819\n"
    },
    {
      "commit": "fbc2d05729376703852806677e5655d333f7a1a4",
      "tree": "e26ae58973936e2a77e66fa63b38dae900803214",
      "parents": [
        "fdaa773088b68f53632070aecac23d3b14b02ec9"
      ],
      "author": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Wed Oct 30 10:13:09 2019 -0700"
      },
      "committer": {
        "name": "Woojoong Kim",
        "email": "woojoong@opennetworking.org",
        "time": "Thu Oct 31 00:43:41 2019 +0000"
      },
      "message": "COMAC-283 Decouple SRIOV device plugin from omec-data-plane\n\nChange-Id: Idf43e06300254fe997692d5a21df895597794219\n"
    },
    {
      "commit": "c4a7d5455f5501a3791c8ebc8df571d79ae0f637",
      "tree": "e37dd4808a6921f8eadc799d298cf36367d43e9d",
      "parents": [
        "7a921d11ba80316f4b2dc52aaf4402f03d6d1c72"
      ],
      "author": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Thu Aug 22 18:53:40 2019 -0500"
      },
      "committer": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Sun Aug 25 17:45:29 2019 -0500"
      },
      "message": "COMAC-168,COMAC-171 [omec-dp] Change sriov configs and enable nodePort\n\n- Change sriov configs to help user configure more easily\n- Enable nodePort for CP-DP communication when CP and DP are deployed in\n  separate clusters, diabled by default\n\nChange-Id: I0e2520d66f2240a2888673d930487dcf112861a0\n"
    },
    {
      "commit": "7a921d11ba80316f4b2dc52aaf4402f03d6d1c72",
      "tree": "7ee12f44efa69009292598517e7ae9379c720761",
      "parents": [
        "43eadccbc1defc8609bdf0fc81c67ff290f27598"
      ],
      "author": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Wed Aug 21 20:52:09 2019 -0500"
      },
      "committer": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Fri Aug 23 13:39:13 2019 -0500"
      },
      "message": "COMAC-168,COMAC-171 Assign static IP to S1U and SGI iface on SPGWU\n\nSPGWC requires S1U address of SPGWU in its configuration. When they are\ndeployed in a separate cluster, SPGWC cannot consult K8S for the IP\naddress like it is doing now. This is a temporary fix until we add an\nability to support multiple instances of SPGWU and load balancer for them.\nAlso, rename/restructued network related values in omec-data-plane/values.yaml\nand use the values directly from configmap instead of passing them as an\nenvironment variable.\n\nChange-Id: Ib02017408c1671e9a003b0f6dc77e4b4d5dad070\n"
    },
    {
      "commit": "7a007bb0984799c8fa2b66bf9628251652b079d5",
      "tree": "131dd073e51272018d591dd95324f34d06cf2fa1",
      "parents": [
        "d8804b3c1d457427c1c03540c8653c4bf755764b"
      ],
      "author": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Mon Aug 19 16:41:36 2019 -0600"
      },
      "committer": {
        "name": "Hyunsun Moon",
        "email": "hyunsun@opennetworking.org",
        "time": "Fri Aug 23 13:39:13 2019 -0500"
      },
      "message": "COMAC-171,COMAC-172,COMAC-173 Restructure mcord-release charts\n\nDone\n- Rename mcord-services to omec\n- Split mcord-services to omec-data-plane and omec-control-plane\n- Merge mcord-setup to omec-data-plane chart\n- Move cdn-services outside of omec\n- Work fine in single cluster\n\nTo do\n- Make it work in multi-cluster\n\nChange-Id: Ic91d7732b844347b9f0a78a97b5d6d888d00887b\n"
    }
  ]
}
